Thermometers | All s.s. remote | TCX - S Art. TCX - STAINLESS STEEL U-Clamped | Bart

TCXS

Print the data sheet Download Request quotation


Code

TCX - S

Use

Temperature is an important variable in many industrial processes, and therefore there is a need for reliable instruments, built to guaranteed standards with little or no maintenance requirements

Description

ALL STAINLESS STEEL Inert gas Thermometer made according UNI EN 13190 norms
- Aisi 304 case, aisi 304 ring, Glass windows, IP55 protection degree
- Dial 63 - 80 -100 - 150 mm
- BACK connection with U-CLAMP for PANEL mount
- Aisi 316 capillary and process side
- Centigrade degree scale. Aluminium dial, white background and black number
- Accuracy 1%

Using range

Ambient temperature -20+60°C (-4+140°F). Over consider 0.05% per °C as termic deviation
Overrange: +30% F.S. for temperature ≤400°F (700°F), max 500°C (900°F)
Thermowell PN 300 bar (4300 psi)

Models

Normalized range in °C: -100+60; -40+60; -40+40; -30+70; -30+50; -30+30; -20+120; -20+60; -20+40;
0+60; 0+80; 0+100; 0+120; 0+150; 0+200; 0+300; 0+400; 0+500; 0+600° C

Options

ATEX version CE Ex II 2 GD c TX, Protection degree IP65; Panel or Wall flange; U-Clamp; Lenght until 15 Mt. NPT connection; Elettric switch; Glycerin; SAFETY GLASS

Available sizes

VAR B D D1 E G L W CH
dn 63 42 61 70 Min. 1 Mt 1/2" BSP Min. 50 12/14 24
dn 80 49 79 90 Min. 1 Mt 1/2" BSP Min. 50 12/14 24
dn 100 47 99 114 Min. 1 Mt 1/2" BSP Min. 50 12/14 24
dn 150 53 149 165 Min. 1 Mt 1/2" BSP Min. 50 12/14 24

CE

SWITCH Standard

Chemical compatibility

Which elements are suitable with materials of process wetted parts
Leggi


Picture, dimensions and features could change at any time

Copyright © 2024 BART S.r.l. - Via Pietro Magistretti, 9 - 20128 Milano (Italia) Tel. +39.02.27206577 - Fax +39.02.25902084 - info@bart-e.com

Privacy and Cookies

BART S.r.l - Via Pietro Magistretti, 9 - 20128 Milano (Italia) Tel. +39.02.27206577 - Fax +39.02.25902084 - info@bart-e.com